Applications

Concrete Production

Concrete mixing facilities use Dynatrol® CL10-DJ Level Detectors to measure high, intermediate, or low levels of various media types in the concrete production process.

Bulk Solids Level Measurement

The Dynatrol® CL10-DJ series of level detectors are used for high, intermediate, or low level detection of bulk solids. Applications in concrete mixing facilities may include:

  • Concrete and mortar mix
  • Sand
  • Gravel
  • Crushed stone
  • Recycled crushed concrete
  • Other aggregates

Our CL10-DJ level switches are made from high strength stainless steel. These switches are used as ‘point level’ indicators and have dry Form C contacts.

Have Questions? We Have Answers!

* required field

Textiles

Our Density Measurement Systems are used to measure various types of media in the textile industry.

Density Measurement

The Dynatrol® CL10-HY Density Cell and Series 2000 Density Digital Converter can be used to measure the density, specific gravity, Baumé, or percent concentration at process conditions of caustic soda concentration and other textile chemicals. Applications may include:

  • Bleaches
  • Rinses
  • Sodium hypochlorite
  • Degree twaddle – textile hydrometers
  • and more...

Have Questions? We Have Answers!

* required field

Terephthalic Acid

Dynatrol® provides Bulk Solids Level Detection for terephthalic acid applications in plants where the acid in the powder form is air transported. Dynatrol® Density Systems are used in terephthalic acid applications in siutations where the acid is carried as a slurry.

Bulk Solids Level Measurement

The CL-10DJ series level switches are used for terephthalic acid applications in plants where the acid in the powder form is air transported . The level switch can detect the presence of the acid powder it comes in contact with and then engage a remote alarm or light to indicate that a hopper or other vessel is full or empty.

Our standard level switches are made from 316 stainless steel. For more abrasive or more corrosive service they can be constructed from other materials.

Density Measurement for Liquids & Slurries

The CL-10HY Series Density Cells are used in terephthalic acid applications in plants where the acid is carried as a slurry. The density cells can detect the exact density of the acid/ liquid combination and can be used to either control the dilution of the slurry or alert operations when the proper concentration is reached. The standard density cells are made with 316 stainless steel media contact materials.

For more abrasive or more corrosive service can be made from other materials.

Have Questions? We Have Answers!

* required field

Viscosity Systems

Dynatrol® Viscosity Systems provide fast, precise measurements for a variety of process Industry applications. The Dynatrol® process utilizes a unique vibratory principle to continuous measurement at on-line process conditions.

Dynatrol® manufactures viscosity systems for measurement of the following process applications:

  • Acetate Dope
  • Acetone Based Emulsion
  • Acrylic Slip
  • Adhesive Rubber Coating
  • Amines
  • Ammonium Diuranate
  • Aniline Residue
  • Animal Glue
  • Aqueous Coating, Clay Latex
  • Aqueous Emulsion
  • Aqueous, Suspension Fiberglass
  • Asphalt
  • Asphalt Coating
  • Asphalt Emulsion
  • Asphalt, Stone Dust
  • Asphalt, Tar Product
  • Asphalt/Limestone
  • Asphalt/Rock Dust
  • Asphaltene, Resin Slurry Oil
  • Asphalts, Clarified Oil
  • Back Coat
  • Batter
  • Bitumen/Kerosene, Bitumen
  • Bitumen/Water Emulsion
  • Black Liquor
  • Black Liquor Sludge
  • Black Liquor Soap Interface
  • Bright Dip Bath
  • Bunker C Fuel Oil
  • Carbon Soot Slurry
  • Carbon, Oil Slurry
  • Casein, Photoresist
  • Cellulose Acetate Dope
  • Ceramic/Metallic Slurry
  • Chocolate Syrup
  • Coal Tar Pitch
  • Coal, Char Water
  • Colloidal Dispersion
  • Conformal Coatings, Solvents
  • Contact Cement
  • Corrugator Adhesive
  • Cosmetics
  • Cough Syrup
  • Crude Oil, Crude Blends
  • Epoxy Resins
  • Ethanol, Stillage
  • Evaporator Bottoms
  • Fatty Acids
  • Filled Asphalt
  • Floculant Cyanamide
  • Fuel Oil
  • Gelatin
  • Glue
  • Gluten
  • Gravy - Petfood
  • Guar Gum, Carboxymethylcellulose
  • Inks
  • Iron Oxide Slurry
  • Isocyanate
  • Latex
  • Lube Oils
  • Methane Diisocyanite
  • Methyl Chloroform
  • Methyl Methacrylate Monomer
  • Methylene, Diparaphenylene
  • Molten Polyester
  • Molten Polyethlyene
  • Molten Polymer
  • Monomers
  • Nitrile Latex
  • Phenolic Resin
  • Photo Resist
  • Plastisol
  • Polyamide
  • Polybutane
  • Polybutylene
  • Polyester
  • Polymers
  • Polypropylene
  • Polystyrene
  • Polyvinyl Acetate Emulsion
  • Polyvinyl Alcohol
  • Potassium Silicate Soln
  • Protein Slurry Loaner
  • Shampoo, Conditioner
  • Sodium Hypochlorite
  • Sodium Perchlorate
  • Synthetic Rubber
  • Terpene Resin
  • Textile Size
  • Thermal Cure Coating
  • Urethane Resin
  • Varnish

Have Questions? We Have Answers!

* required field

Nitric Acid

The Dynatrol® CL10-HY Density Cell and Series 2000 Density Digital Converter can measure the temperature and density of a nitric acid process stream.

How it works: The Series 2000 Digital Density Converter processes basic information from the Density Cell to calculate density at a reference temperature. The process value can be used to calculate the specific gravity, Baumé and percent concentration. This information is made available to the operator or process engineer.

The standard Series 2000 has an analog output corresponding to either of these process variables. Optionally, it can be programmed to have two analog outputs that can be calibrated for any two process variables (Density, Temperature, Baumé, Specific Gravity, Percent Concentration).

Have Questions? We Have Answers!

* required field