Applications

Ethylene Glycol

The Dynatrol® CL-10HY Density Cell and Series 2000 Digital Density Converter can measure the temperature and density of an ethylene glycol process stream. Applications may include antifreeze and deicing fluid, also for use in manufacturing of resins and polyester fibers in the plastics industry, as well as removing water vapor during natural gas production.

How it works: The Series 2000 Digital Density Converter processes basic information from the Density Cell to calculate density at a reference temperature. The process value can be used to calculate the specific gravity, Baumé and percent concentration. This information is made available to the operator or process engineer.

The standard Series 2000 has an analog output corresponding to either of these process variables. Optionally, it can be programmed to have two analog outputs that can be calibrated for any two process variables. (Density, Temperature, Baumé, Specific Gravity, Percent Concentration)

Have Questions? We Have Answers!

* required field

Power Plant

Dynatrol® instruments provide Bulk Solids Level Measurement of fly ash applications, Density Measurement of water treatment chemicals, various liquors and lime slurries and Viscosity Measurement of fuel oil and waste oil.

Bulk Solids Level Detection

Dynatrol® CL-10DJ series level switches are used for fly ash applications in power generation plants and for fly ash collection. These level indicators are also used in applications where fly ash is used as a filler. Our CL-10DJ level probes are made from high strength stainless steel. For more abrasive or corrosive service, our level switches can be made from other materials. These level switch probes are well suited for the high temperature and harsh environments that are always a part of fly ash applications.

Density Measurement

The Dynatrol® CL-10HY Density Cell and Series 2000 Digital Density Converter can be used to measure density, specific gravity or percent solids of water treatment chemicals such as caustic soda or sulphuric acid. Our equipment is also used to measure black liquor, green liquor and lime slurries, etc. at process conditions.

Our application software is written to use temperature and density information that comes from the CL-10HY cell to calculate various units at process conditions

Viscosity Applications

The Dynatrol® CL10-DV series Viscosity Meter and Series 3000 Viscosity Digital Converter are used to measure the viscosity of fuel oil in fuel oil to burner applications. Thus, helping to increase combustion efficiency and decrease particulate emissions. Dynatrol® Viscosity Systems are also used in waste oil incineration and waste oil pumping applications.

Have Questions? We Have Answers!

* required field

Sodium Hydroxide – Caustic Soda

The CL10-HY Density Cell in conjunction with the Series 2000 Density Digital Converter can measure the temperature and density of a caustic soda (sodium hydroxide) process stream. The Series 2000 then processes this information.

Once the information is processed the density is calculated at a reference temperature. The specific gravity, baumé and percent concentration are then calculated from the reference temperature and the density at the reference temperature and this information is made available to the operator or process engineer.

The standard Series 2000 has a analog output corresponding to either of these process variables. Optionally, it can be programmed to have two analog outputs that can be calibrated for any two process variables (Temperature, Baume, Specific Gravity, Density, Percent Concentration, °Twaddle).

Have Questions? We Have Answers!

* required field

Pipeline

Dynatrol® Density Systems are used worldwide in pipeline applications for measurement and control of density, specific gravity, API gravity or percent concentration. Typical applications are custody transfer or interface measurement and may include crude oil, refined products or various other chemicals.

Dynatrol® Density Cells are used to measure the liquid being transported in the pipeline. The Cell’s operation is extremely accurate and dependable, requiring no pressure compensation.

Working with the Density Cell, the Dynatrol® Digital Density Converter translates the product density and temperature readings into the customers’ required units of measurement. For example, if a United States pipeline requires the American Petroleum Institute (API) scale or a Canadian Pipeline requires output in kilogram per cubic meter (kg/m 3), Dynatrol® electronics are programmed for each application’s specific measurement needs.

The Dynatrol® Systems are user-friendly. Converters come pre-programmed for simple calibration. Many Dynatrol® Density Cells have sustained accuracy in the field without need of service for over 20 years!

Have Questions? We Have Answers!

* required field

Interface Level

Typical applications include WATER/CARBON, WATER/SAND, LIQUID/CATALYST INTERFACES and those that occur in steeping processes.

The Dynatrol® CL-10DJI Interface Level Detector has the unique ability to detect:

  • a liquid and settled bed of solids
  • a liquid and floating bed of solids
  • the liquid phases of products having significantly different viscosities

Used on the following applications:

  • Bead/waterblack
  • Black liquor/soap
  • Brine/salt
  • Carbon/water
  • Clay/water
  • Coal/coal water slurry
  • Corn/water
  • Pellets/water
  • Polymer grade lactic acid/water
  • Resin/water
  • Rice/water interface
  • Salt/water interface
  • Sand/water
  • Shell/water
  • Sodium sulfate crystal/water
  • Water, oil/metal fines

Have Questions? We Have Answers!

* required field